The Reference Methods
The diagrams show how to establish references with duplex launch cables.
Each method will produce slightly different results.
It is very important that the transmitter connections are not disturbed after
the reference value is established. To assure that the effects of the connec-
tors and launch cables are “zeroed out”, follow the instructions closely.
Note: When a connector is removed and then reattached, it is unlikely to go
back into the exact same position. As a result, measurements will change
when connections are made or broken.
OMNI
Scanner
measures two fibers at the same time in a duplex link. Two
reference values will be stored, one from OMNI
Scanner
to OMNI
Remote
(TX
- RX), the other from OMNI
Remote
to OMNI
Scanner
(TX - RX).
Method A
When Method A is used, the effects of the two launch cables and the
couplers are canceled for all subsequent measurements.
1. Connect a Launch Cable to the fiber adapter that is attached to OMNI-
Scanner. The black fiber attaches to the TX (transmitter) side and the
white fiber to the RX (receiver) side.
2. Connect a Launch Cable to the fiber adapter that is attached to OMNI-
Remote. Now the black fiber attaches to the RX (receiver) side and the
white fiber to the TX (transmitter) side.
3. Use a Coupler to connect the two black fiber ends.
4. Use a Coupler to connect the two white fiber ends.
5. Set the Reference.
RX
TX
850 nm
1300/1310 nm
RX
TX
850 nm
1300/1310 nm
2 m Launch Cable
2 m Launch Cable
Coupler
