User guide
OMNIScanner User Guide
4 - 14
are displayed for both wavelengths.
For dual fiber testing the arrows RQ at the top of the screen point out the
direction of the light and indicate which fiber the result is for.
Note: When measuring single-mode fiber cables OMNIScanner displays
results for one wavelength; the upper (850 nm) section will be blank.
Press ESC to exit the LOSS screen.
Power Meter
The Power Meter function reports the overall power. Use it to quickly verify
and correct cabling and equipment problems.
The POWER METER screen shows the currently selected wavelength and
light source mode.
The overall power is displayed.
OMNI
Fiber
is designed to provide a consistent,
calibrated light source for effectively measuring
signal loss in fiber optic cables. The transmitted light
can be operated continuously or modulated.
When testing loss, use the continuous light source,
when identifying fiber cables with a tone locator, use
the 2KHz modulated mode.
Press (Continuous) or (Modulated) to change the light
source.
Press or to change the wavelength.
Press to find the reference value, place it in the appropriate field,
and start calculating the loss.
Press ESC to exit the POWER METER screen.