User guide

OMNIScanner User Guide
3 - 4
The first page displays the Configuration of the
Autotest (Basic Link, Channel, or Permanent Link).
Wiremap, Length, Delay and Skew limits are also
displayed. The Wiremap numbers show the pairs
that are being tested.
The second page shows limits for Resistance,
NEXT, Attenuation, and Return Loss.
The third page lists limits for ELFEXT, ACR, and
Power Sum NEXT measurements.
The fourth page shows limits for Power Sum
ELFEXT and Power Sum ACR. This screen also
informs you whether or not OMNI
Remote
is required
to perform the selected Autotest.
The screen title shows the standard being used to
set the limits (e.g. Cat 6 Link-D3).
Test that are performed during an Autotest are
clearly marked . Tests that are not required when
performing an Autotest have no icon.
Disabled tests may or may not show limits in the
description field. An precedes the test name for
tests being performed during the Autotest, but the
results are not used to determine PASS or FAIL.
Defined test limits will be displayed right below the
test name. If a test has no limit, the limit description
field will be empty.
For fiber optic cabling the View Autotest Detail
screen shows the standard being used in the titlebar.
The test that are performed during an Autotest are
clearly marked .
If an precedes the test name, the test will be
performed for information purpose only, the results