User guide
2 - 9
OMNIScanner User Guide
Viewing Twisted Pair Autotest Results
This viewing option is only available immediately after the Autotest was
performed. To view stored test results at a later time, press the
(Results) function key located in the Project screen.
(See Chapter 6 -
Results for more information.)
Note: The list of tests varies depending on the kind of Autotest that was
performed.
1. To view detailed results of all the tests that were performed during
Autotest, highlight a specific test in the Autotest screen using the é or ê
and press ENTER.
2. Use the ç or è to quickly browse through all other detailed test result
screens and their results.
All Tests that can run during Autotest are displayed on the previous page.
(See Chapter 4 - Measurements for detailed descriptions of each available
test.)
Most Autotest result screens have a retest feature for diagnostic purposes.
Press (Retest) to run continuous tests for the same cable. The
arrow located on the Retest button will be turning for the duration of the
test.
Press (Retest) once more to stop the continuous measurement.
OMNI
Scanner
will display the last measured data.
Note: Retest invalidates an Autotest. After using the retest feature, the
Autotest must be repeated before results can be saved.
The NEXT, Attenuation, Return Loss, Power Sum
NEXT, ELFEXT, ACR, Power Sum ELFEXT, and
Power Sum ACR test result screens have a graph
feature to display the graph associated with the test.
To avoid misinterpretation, the limit line is shown in
a gray color, while the actual measurement is
represented in black.
Press (Graph) to display a graph for a pair or a pair combination.