User guide

2 - 5
OMNIScanner User Guide
6. Select the cable type to be tested from the
drop-down list and press ENTER.
The field Adapter: will automatically change to
reflect the adapter that is currently attached.
Every Project has certain Autotests and
cables assigned already. These associated
lists will appear in the drop-down lists for each
item. If the Autotest or Cable you want to use
is not in a drop-down list, open (Setup) to select the appropriate
item.
(See Chapter 3 - Setup: Autotest, Cable, or Project for further
information.)
Note: When using an Autotest or a cable that was selected from a Setup
menu and not from a predefined drop-down list, the Autotest or cable will
not be stored within the project.
Running an Autotest for Twisted Pair Cabling
(See Chapter 8 - Fiber Optic Autotests for information on running, saving,
and viewing Fiber Optic Autotests.)
1. Connect OMNI
Scanner
to the
near end of the twisted pair cable
you are testing and connect
OMNI
Remote
to the far end.
(See the Typical Test Configura-
tions for Twisted Pair Cabling
section in this chapter for more
information.)
2. Press the
AUTOTEST
key.
When testing twisted pair cable,
OMNI
Scanner
will immediately
verify that OMNI
Remote
is
attached. If OMNI
Remote
is not
attached, OMNI
Scanner
will wait
until it is attached before running
the Autotest.
Modular 8 Jack
Modular 8 (RJ-45)
plug to 160-pin
Test Cable
 