User guide
C - 1
OmniScanner User Guide
Appendix C - OMNIFiber PASS/FAIL
Criteria
Autotest Maximum Maximum Maximum
850nm 1300nm Prop.
Loss Loss Delay Length
TIA 568A Formula 1* Formula 2* N/A 2000m
11801 Equation Formula 3* Formula 4* N/A 1500m
1000Base-SX 3.9dB N/A N/A 550m
50 micron
1000Base-SX 3.2dB N/A N/A 220m
62.5 micron
1000Base-LX N/A 3.5dB N/A 550m
50 micron
1000Base-LX N/A 4.0dB N/A 550m
62.5 micron
ATM 155 N/A 10.0dB N/A. 2000m
ATM 155 SWL 7.2dB N/A N/A 1000m
ATM 622 (62.5) N/A 6.0dB N/A. 500m
FDDI N/A. 11.0dB N/A 2000m
100Base-F N/A 11.0dB N/A. 2000m
10Base-FL 12.5dB N/A 10,000ns 2000m
10Base-FB 12.5dB N/A 10,000ns 2000m
Token Ring 13.0dB N/A N/A 2000m
Fiber Channel** N/A 6.0 N/A 175m
*See Formula Explanation on next page.
**See the data rate table on next page for further information