Specifications
ATAPI For Streaming Tape QIC-157 Rev B
81
6.8.10. READ POSITION Command
The READ POSITION command reports the current logical position of the Device. No medium
movement shall occur as a result of the command.
Table 6-59 Read Position Command
Bit
Byte
7 6 5 4 3 2 1 0
0 Operation code (34h)
1 Reserved 0 (BT)
2 Reserved
3 Reserved
4 Reserved
5 Reserved
6 Reserved
7 Reserved
8 Reserved
9 Reserved
10 Reserved
11 Reserved
A Block Type (BT) bit of zero indicates the value(s) returned in the Read Position Data , First and
Last Block Location fields shall be interpreted as a sequential logical block address(es) with block
zero originating at the beginning-of-partition.
If the Device is not capable of reporting block locations, the BPU bit shall be set to one in the returned
data. A REWIND/LOCATE operation may recover from this condition.
The READ POSITION data shown in Table 6-60 shall be returned as data after the command.