Technical information
Section 2
Feature Highlights
*Extended Input Voltage Range of 135~300 volts : When the voltage fluctuates to as low as 150 volts & as high as 290 volts, these UPS
give you the corrected line voltage output of 230 volts ± 9% and don't switch the UPS to "Battery Backup mode" like most other UPS.
Smart Boost function for Low Input Voltage : When the mains voltage is low, the smart boost will correct it back to its normal range
without draining the internal battery.
Smart Buck function for High Input Voltage : When the mains voltage is high, the AVR or smart buck will correct it back to its normal
range without draining the internal battery.
Over Voltage Protection: The UPS will switch to backup mode & offers power from its internal battery when the mains voltage is too high.
No Load Shutdown: In case No load is connected to the UPS, it will sense the load condition and automatically Shut Down after 3
minutes to protect unnecessary discharge of the battery. (This feature in Heritage Gold and Bravo model only)
Over Load / Short Circuit Protection : If the UPS is excessively overloaded in backup mode or encounters a short circuit, it will go into
protection mode. The output will be shut down in this case.
Battery Deep Discharge / Over Charge Protection : The UPS has in-built electronic protection circuit which protects the batteries from
getting deep discharged or over charged.
Battery Backup/Rating Table
*In Heritage+ , Heritage Gold and Bravo Models the Input Voltage Range is 145~300V.
3
Model HERITAGE / HERITAGE GOLD / BRAVO 2BATTERY DOUBLE POWER
Battery Rating 12V, 7.2AH/7AH 12V, 7.2AH/7AH x 2
Approx. Backup Time 10~20 Min. (1PC) 25~50 Min. (1PC)