Technical information
Section 11
Technical Specifications
* Above specifications are measured under computer load. * Specifications are subject to change without notice.
14
MODEL Heritage / Heritage Gold / Bravo MDP800
Input Range / Frequency(50Hz+5%) 145~300V AC 135~300V AC
Output Voltage / Transfer Time 230V+9% AC / <6ms
Regulator on Mains / Regulator on Battery Automatic Voltage Regulation / Pulse Width Modulation
Protection Unit Input / Noise / Fuse Protection / Noise Filter
Short Circuit (Line) / Short Circuit (Inverter) Fuse Protection / Pulse to Pulse Electronic active Protection
Battery Type / Recharge Time SMF / 2~8 Hrs. (depending on the status of Battery)
Backup Time/ Batery Rating Refer Backup Table in Section 2
Alarm Battery Backup (Sound beeping) per 8 sec. (Approx.) per 20 sec. (Approx.)
Battery Low Sound beeping long
LED Display Green Mains mode operation / AVR Working
Red Inverter output from battery
Physical Size (L x W x H) (300x90x145)mm (350x125x170)mm
Weight (Approx.): Heritage / Heritage Gold / Bravo : 6Kg. MDP800 : 11Kg.
0 0 0 0
Environment Operating Temperature / Rel. Humidity 0 C ~ 48 C ; 32 F ~ 120 F / 0 to 90% non-condensing
Noise Audible Noise level <35dB, distance 1 meter from UPS