Specifications
4
Daily setup flow
Make a test print. (22-step setup print)
Colorimeter calibration (auto)
Sensor LED Light Intensity Adjustment
Measure a test print
When the light source
upgrading (auto) is
carried out correctly
during the program
timer
Light source upgrading
When the light source
upgrading (auto) is
not carried out
correctly during the
program timer
3020
33_3
Registration
Explanation
• After exposing the test print, the calorimeter calibration will be executed automatically.
• The light source update is executed automatically for the carrier to be set during the program
timer.
e.g.) When 240 lane is set: 240 light source update is executed.
When 120 AFC is set, 120 light source update is executed.
• When the light source update is not completed correctly during the program timer, it is executed
again automatically for the carrier to be set during the daily setup.
Note
• As for the other carriers except the one to be set during the program timer, update the light
source when replacing the carrier or switching the lane.
Yet, it is necessary to perform the Light Source Update when using the film carrier 24 hours
after the last performance of the Light Source Upgrade.