Appendix B: Troubleshooting...
15 Problems with the Transparent Media Adapter (TMA).
Solution: If you have a ScanMaker III scanner, make sure the TMA cable
is connected on the back of the ScanMaker III scanner and that the screws
are very tight. Otherwise, it is possible that the TMA may not work.
16 The Color Correction button is grayed out and you cannot select it.
Solution: This button turns gray when the DCR or Dynamic Color
Rendition files are missing from the Windows/Twain/Microtek/DCR
directory. To fix this problem, run the calibrator program and calibrate
your scanner, or reinstall the ScanWizard so that the default profiles are
copied onto your system. A new set of profiles will then be generated.