Specifications
Q-60E3 KODAK
EKTACHROME
Professional Film
IT8.7/1-1993
2001:03
35.8
Kodak
Calibration Setup
1. With the target properly positioned on the scanner, turn on your scanner and let it
warm up for about five minutes.
2. Launch the Scanner ICC Profiler calibration utility. When the main MSP dialog
window appears, do the following:
A Choose the scanner model you are currently calibrating.
B Choose the proper target media. Select Positive.
C Select the date code and target type from the drop-down list that match your
target. You can verify this information by looking at the left and right corners of
the target's bottom margin.
C
B
F
A
D
E
Note
::
::
: If you are unable to find the target type with date code that matches the target you
are using, find the Target Profile CD that came with your scanner.
For Macintosh, run the Macsetup program on the CD.
For Windows, run Winsetup.exe on the CD, then restart MSP. The target type with your
date code should now be available from the selection list.