Table 2 lists the standard addresses and IRQs assigned by the Setup
program for each COM port. If these values do not match your
configuration, select Custom and enter the correct address and IRQ.
You can also specify a non-standard address if used by your
configuration.
Table 2. COM Port IRQs and Addresses Used by the Setup Program
COM Port IRQ Address Comment
COM1 4 3F8
COM2 3 2F8
COM3 5 3E8 Uses IRQ5, not IRQ4.
COM4 2 2E8 Uses IRQ2, not IRQ3.
COM5 2E0
COM6 2F0
COM7 3E0
COM8 3F0
Use the baud rate setting to specify the baud rate for the COM port
through which the touchscreen driver communicates with the
touchscreen controller and touchscreen.
Note:
The touchscreen controller must be set to use the same baud
rate as the COM port. If the baud rates are different, the touchscreen
driver and the touchscreen controller cannot communicate. To change
the baud rate for the controller, use Microcal. The default baud rate
for all MicroTouch controllers is 9600.
For more information about using Microcal, refer to Chapter 4.