User`s guide
Chapter 5 Troubleshooting the Touchscreen 127
touchscreen driver so that they match those of the controller. If
you are using Custom communication settings, be sure that the
base address is correct.
After changing the communication settings, reboot the system.
For more information on Microcal, refer to Chapter 4. For more
information on the Touchscreen Control program, refer to
Chapter 2.
You specified the wrong communication settings during
installation. Use Microcal to check the touchscreen controller’s
COM port, baud rate, and IRQ. Use the Hardware Controls
dialog box in the Touchscreen Control program to modify the
communication settings used by the touchscreen driver so that they
match those of the controller. If you are using Custom
communication settings, be sure that the base address is correct.
After changing the communication settings, reboot the system.
For more information on Microcal, refer to Chapter 4. For more
information on the Touchscreen Control program, refer to
Chapter 2.
Error: The touchscreen driver is not loaded.
This is the same as the error
TNDRIVER not loaded
. Refer to that
error description for more details.
Error: The hardware resources for
Irq/Port
are already in use by another
driver.
Another device is using the same COM port, IRQ, or base address as
the touchscreen controller. Use Microcal to specify unique
communication settings for the touchscreen controller. Use the
Hardware Controls dialog box in the Touchscreen Control program to
modify the communication settings used by the touchscreen driver so
that they match those of the controller. If you are using Custom
communication settings, be sure that the base address is correct.
After changing the communication settings, reboot the system.
For more information on Microcal, refer to Chapter 4. For more
information on the Touchscreen Control program, refer to Chapter 2.