User guide
Company confidential proprietary information. Do not distribute.
© 2009 Microsoft Corporation, all rights reserved.
SenseCam v2.3 User Guide Page 28 of 31 10/03/2009
Config1 byte [eewrite address 9]
1
1
1
1
1
1
1
1
default factory-programmed value: 0xFF
Control
b7
b6
b5
b4
b3
b2
b1
b0
Description
Camera power
saving
bitmask 0x01
0
Turn off camera power saving. The internal camera
sensor is not turned off after each image capture. This
may be marginally faster.
1
Turn on camera power saving. The internal camera
sensor is turned off after each image capture to conserve
battery power. This is the default setting.
Camera
reinitialisation
0
Turn off camera re-initialisation. Prevents re-
initialisation of the internal camera sensor prior to each
and every image capture. This may be marginally faster.
bitmask 0x02
1
Turn on camera re-initialisation. The internal camera
sensor is re-initialised prior to each and every image
capture. This is particularly required if the sensor has
been powered down due to camera saving (see above).
This is the default setting.
b7
b6
b5
b4
b3
b2
b1
b0
Figure 19: SenseCam config1 byte (address 9) bit fields and their meanings.