User Manual
Wireless Platforms
CM/BU 8 (10)
RD-1/RD-2 handling guidelines for OEMs Print Date: 1/15/2007 Copyright © 2007 Nokia.
6.2 Antenna Connection
The antenna coaxial shall be connected only after the module has been seated in the host laptop and according to
the following steps below:
1. Offer the female plug up to the module socket ensuring that the barrels of both connecting parts are
parallel.
2. Press gently on the back plate of the female plug in the same plane as the barrels of both connecting parts.
3. Remove pressure as soon as the connection is made. The connection is made when a click is felt.
NOTE: Excessive twisting moments during connection may result in damage to the internal conductors.
NOTE: No strain should be placed upon the antenna coaxial or female plug.
Figure 6: Safe Load and Support Points (Antenna Connection)
6.2.1 Maximum Safe Load (Antenna Connection)
The maximum pressure applied to the point shown in Figure 6 and the resulting deformation shall not exceed that
shown in the table below:
Maximum Safe Load
(N)
Corresponding
Maximum Safe
Deflection (mm)
30 < 0.55
Table 2: Maximum Safe Load and Resulting Deformation (Antenna Connection)
X
X Safe Load Point
Fixed Support Area