Specifications

Doc Number: VIS-ANA-VER-01001-9002
Date: 27 May 2004
Issue: 5.0
Page: 2 of 80
Author: J. Delgadillo
Controls Preliminary Design Report Issue 5.doc
Change Record
Issue Date Section(s) Affected Description of Change/Change Request
Reference/Remarks
1.0 08/08/03 All First Issue
2.0 08/20/03 Table 4.2.C Axis Limits, per RID No. TELS_PDR_29
2.0 08/20/03 4.2.2.4 Regeneration Cabinet, per RID No. TEL_PDR_24
2.0 08/20/03 4.2, Table 4.2.2.2.B and C AZ/ALT Initialisation, per RID No. TELS_PDR_40
2.0 08/20/03 Table 4.2.2.2.B and C,
Table 4.2.2.3.B
PDU to LCU Interface, per RID No. TELS_PDR_51
2.0 08/20/03 4.2.2.7 Table Corrected power supply vendor and part number
2.0 08/20/03 3 Added AD10 reference
2.0 08/20/03 4.2.1 Revised LVD & EMC Table
3.0 08/28/03 4.2.2.1.9 Per TELS_PDR_79 RID, meaning of “disable” has been
clarified.
3.0 08/28/03 4.2.2.1.13 Per TELS_PDR_80 RID, LCU Mode section has been
amended.
3.0 08/28/03 4.2.2.9 Per TELS_PDR_38 RID, the PMU section has been
amended.
3.0 08/28/03 4.2.2.2 Per TELS_PDR_82 RID, correction to show that the Alt
rate feedback is the derivative of encoder feedback
3.0 08/30/03 4.2.2.2 Per TELS_PDR_105 RID, added Preload Scheme Plot
3.0 08/30/03 Table 4.2.C Per TELS_PDR_123 RID, AD03 calculations changed.
AD03 updated values are updated here.
3.0 08/31/03 Table 4.2.C Per TELS_PDR_104 RID, AD03 calculations changed.
AD03 updated values are updated here.
3.0 08/31/03 4.3.2 Per TELS_PDR_89 RID, the Altitude encoder-sitting
circumference updated.
3.0 08/31/03 Table 4.2.2.2.B and C,
Table 4.2.2.3.B
Added Single Motor message per RID No.
TELS_PDR_88
3.0 09/15/03 Table 4.2.2.2.B and C,
Table 4.2.2.3.B
PDU to LCU Interface, per RID No. TELS_PDR_51
Contractor’s comments
3.0 09/15/03 4.2.2.2 AZ Bearing Lube Pump description, per RID No.
TELS_PDR_22
3.0 09/15/03 4.2, 4.2.2.2, 4.2.2.3 Proposed LCU Interface change per RID No.
TELS_PDR_40
3.0 09/15/03 4.2.2.2, 4.2.2.3, 4.2.2.6 Deletion of Overspeed Detection Unit on AZ and CASS
axis (RID no. TELS_PDR_85 Contractor’s Updated
Response)
3.0 09/16/03 4.2, 4.2.2.1, 4.2.2.9 Per RID No. TELS_PDR_55, moving MCU and PMU
to an Appendix
3.0 09/17/03 Figure 4.2.A Updated Figure 4.2.A
4.0 03/17/04 ALL Extensive Revision to Include Final Design Changes
5.0 05/27/04 Signature Block Per TELS_FDR1_038, modified signature block signees
5.0 05/27/04 4.2.1 Per TELS_FDR1_039, clarified “Activate” terminology
5.0 05/27/04 Various Per TELS_FDR1_040, re -organized doc
5.0 05/27/04 4.2.5.1 6 Per TELS_FDR1_041, added AD11 and corrected
wording for Anemometer interfaces
5.0 05/27/04 4.2 Per TELS_FDR1_043, reworded function of MCU &
PMU
5.0 05/27/04 4.2.8 (new) Per TELS_FDR1_048, added para on break-out boxes
5.0 05/27/04 4.2.4.8, 4.2.5.14 Per TELS_FDR1_087, added Intlk signal to list and