User guide

A Troubleshooting
126 Trimble M3 Total Station User Guide
A.6 Adjustment C&I
A.7 Application
Error message Cause Solution
Value C was out of
tolerance.
The collimation axis error is out of
range.
Press any key to return to the
results screen and then repeat the
observation.
Value i was out-of-
tolerance.
The index axis error is out of range. Press any key to return to the
results screen and then repeat the
observation.
Compensator oper.-range
exceeded.
The compensator was out-of-range
when the measurement was started in
Adjustment C&I.
Press any key to return to the
previous screen. Then, level the
instrument finely and repeat the
observation.
V-Difference too large%
In the Adjustment C&I program, the
observed target was more than +/-
20gon from the horizontal line.
Press any key to return to the
previous screen. Then, set a target
closer to the horizontal. Set
another target and remeasure.
Compensator Out of
tolerance.
The adjustment value for the
compensator is out of tolerance.
Press any key to return to the
previous screen.
Error message Cause Solution
Distance A-B too small.
The distance between point A and B is
less than 10 cm.
Press any key to return to the
Select point B screen.
Use a different point as point B.
Geometrical situation is
undefined.
The angle between A-B and S-A or the
angle between A-B and S-B is less than 9
degrees.
Press any key to return to the
Select point B screen.
Use a different point as point B.