User Guide
Finalizin
g
the Desi
g
n 3
-29
Finalizin
g
the Desi
g
n
This section describes how to use the PSpice Optimizer to:
• Standardize component values once the optimization is
complete.
• Save results.
• Back-annotate the schematic with the final component and
parameter values.
Usin
g
Standard Component
Values
When optimization parameters directly correspond to
component values, you can use the PSpice Optimizer to select
standard component values by either:
• rounding to the nearest values, or
• computing values based on the most recent optimization
run.
The PSpice Optimizer considers the tolerance specified for the
parameters using tables of preferred values for 1%, 5% and 10%
tolerance components. Other tolerance values cause the
optimizer to use the nearest calculated value for that tolerance.
Parameters with zero tolerance are not changed.
To round component values to the nearest
standard values
1
From the Edit menu, select Round Nearest.
Edit menu