4 Port Gigabit Ethernet PoE Switch – User Manual ii ________________________________________________________________________ Table of Contents ELECTRONIC EMISSION NOTICES ................................................................................................................... IV WARNING: ........................................................................................................................................................ IV 1. INTRODUCTION ......................................
24 Port Gigabit Ethernet PoE Switch – User Manual iii ________________________________________________________________________ APPENDIX A TECHNICAL SPECIFICATIONS ..................................................... 70 ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual iv ________________________________________________________________________ Caution Circuit devices are sensitive to static electricity, which can damage their delicate electronics. Dry weather conditions or walking across a carpeted floor may cause you to acquire a static electrical charge. To protect your device, always: Touch the metal chassis of your computer to ground the static electrical charge before you pick up the circuit device.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 1 of 72 ________________________________________________________________________ 1. Introduction 1-1. Overview of 24 Port Gigabit Ethernet Switch The 24 Port Gigabit Ethernet Switch is a standard switch that meets all IEEE 802.3/u/x/z Gigabit and Fast Ethernet specifications. The switch has 20 10/100/1000Mbps TP ports and 4 Gigabit TP/SFP combo ports. All TP ports support IEEE802.3af (PoE 15.4W) and IEEE802.3at (PoE+ 30W) standard.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 2 of 72 ________________________________________________________________________ 1-2. Checklist Before you start installing the switch, verify that the package contains the following: 24 Port Gigabit Ethernet Switch with PoE and WEB management Mounting Accessory (for 19” Rack Shelf) This User's Manual in CD-ROM AC Power Cord Please notify your sales representative immediately if any of the aforementioned items is missing or damaged. 1-3.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 3 of 72 ________________________________________________________________________ 1-4. View of 24 Port Gigabit Ethernet Switch Fig. 1-1 Full View of 24 Port Gigabit Ethernet Switch: MS400830M 1-4-1. User Interfaces on the Front Panel (Button, LEDs and Plugs) There are 20 TP Ports (10/100/1000Base-T) and 4 dual media ports (UTP/SFP) on the front side.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 4 of 72 ________________________________________________________________________ • LED Indicators LED Color Function System/Mode LED System Green Lit when Link/Act Green Lit when Speed Green Lit when PoE Green Lit when +3.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 5 of 72 ________________________________________________________________________ 2. Installation 2-1. Starting up 24 Port Gigabit Ethernet Switch This section will give users a quick start for: - Hardware and Cable Installation - Management Station Installation - Software booting and configuration 2-1-1.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 6 of 72 ________________________________________________________________________ • TP Port and Cable Installation In the switch, TP ports support MDI/MDI-X auto-crossover, so both types of cable, straight-through and crossed-over can be used. It means you do not have to tell from them, just plug it. Use Cat.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 7 of 72 ________________________________________________________________________ 2-1-2-2. Cabling Requirements for 1000Base-SX/LX SFP Modules It is more complex and comprehensive contrast to TP cabling in the fiber media. Basically, there are two categories of fiber, Multimode (MM) and Single Mode (SM). From the viewpoint of connector type, there mainly are LC (standard) and BIDI SC.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 8 of 72 ________________________________________________________________________ • Typical Network Topology in Deployment A hierarchical network with minimum levels of switch may reduce the timing delay between server and client station. Basically, with this approach, it will minimize the number of switches in any one path; will lower the possibility of network loop and will improve network efficiency.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 9 of 72 ________________________________________________________________________ Case 2b: Port-based VLAN (See Fig.2-4). Fig. 2-4 Port-based VLAN Diagram 1. VLAN1 members could not access VLAN2, VLAN3 and VLAN4 members. 2. VLAN2 members could not access VLAN1 and VLAN3 members, but they could access VLAN4 members. 3. VLAN3 members could not access VLAN1, VLAN2 and VLAN4. 4.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 10 of 72 ________________________________________________________________________ 2-1-3. Configuring the Management Agent In the way of web, user is allowed to startup the switch management function. Users can use any one of them to monitor and configure the switch. You can touch them through the following procedures described in section 2-1-3-1. 2-1-3-1.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 11 of 72 ________________________________________________________________________ 2-1-4. IP Address Assignment For IP address configuration, there are three parameters needed to be filled in. They are IP address, Subnet Mask, Default Gateway and DNS. IP address: The address of the network device in the network is used for internetworking communication. Its address structure is shown Fig. 2-8.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 12 of 72 ________________________________________________________________________ Class C: IP address range between 192.0.0.0 and 223.255.255.255. Each class C network has a 24-bit network prefix followed 8-bit host address. There are 2,097,152 (2^21)/24 networks able to be defined with a maximum of 254 (2^8 –2) hosts per network.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 13 of 72 ________________________________________________________________________ Not all IP address is available in the sub-netted network. Two special addresses are reserved. They are the addresses with all zero’s and all one’s host number. For example, an IP address 128.1.2.128, what IP address reserved will be looked like? All 0s mean the network itself, and all 1s mean IP broadcast. 128.1.2.128/25 Network Subnet 10000000.00000001.00000010.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 14 of 72 ________________________________________________________________________ This means it is a small network accommodating a maximum of 15 nodes in the network. Default gateway: For the routed packet, if the destination is not in the routing table, all the traffic is put into the device with the designated IP address, known as default router. Basically, it is a routing policy.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 15 of 72 ________________________________________________________________________ 2-2. Typical Applications The switch implements 24 Gigabit Ethernet TP ports with auto MDIX and four slots for the removable SFP modules. For more details on the specification of the switch, please refer to Appendix A. The switch is suitable for the following applications. Central site/remote site application is used in carrier or ISP (See Fig.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 16 of 72 ________________________________________________________________________ Fig. 2-11 Peer-to-peer Network Connection Fig. 2-12 Office Network Connection ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 17 of 72 ________________________________________________________________________ 3. Operation of Web-based Management This chapter would introduce how to manage your Web Smart Switch and how to configure the 10/100/1000Mbps TP Ports and Gigabit SFP Fiber ports on the switch via web user interfaces. The Web Smart Switch provides 20 fixed Gigabit Ethernet TP ports and 4 Gigabit dual media ports.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 18 of 72 ________________________________________________________________________ 3-1. Web Management Home Overview After login, System Information would be displayed as Fig. 4-2 illustrated. This page lists default values and shows you the basic information of the switch, including “Switch Status”, “TP Port Status”, “Fiber Port Status”, “Aggregation”, “VLAN”, “Mirror”, “SNMP”, and “Maximum Packet Length”.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 19 of 72 ________________________________________________________________________ 3-1-1. Page Layout On the top part of the information page, it shows the front panel of the switch. Linked ports will be displayed in green color, and linked-off ones will be in black. For the optional modules, the slots with no module will only show covered plates, the other slots with installed modules would present modules.
Port Gigabit Ethernet PoE Switch – User Manual Page 20 of 72 ________________________________________________________________________ 3-2. Configuration Configuration includes the following functions: System Information, Ports Configuration, VLAN Mode Configuration, VLAN Group Configuration, VLAN Isolation, PoE, Aggregation, RSTP, IGMP Snooping, Mirroring, QoS, Loop Detection, Broadcast Strom Protection and SNMP. ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 21 of 72 ________________________________________________________________________ 3-2-1. System Information System configuration is one of the most important functions. Without a proper setting, network administrator would not be able to manage the device. The switch supports manual IP address setting. Fig.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 22 of 72 ________________________________________________________________________ Parameter description System Description: The simple description of this switch Firmware Version: The firmware version of this switch Hardware Version: The hardware version of this switch MAC Address: It is the Ethernet MAC address of the management agent in this switch. Serial Number: The serial number is assigned by the manufacturer.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 23 of 72 ________________________________________________________________________ Fallback Subnet Mask: Subnet mask is made for the purpose to get more network addresses because any IP device in a network must own its IP address, composed of Network address and Host address, otherwise can’t communicate with other devices each other.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 24 of 72 ________________________________________________________________________ 3-2-2. Port Configuration Function name Port Configuration Function description Port Configuration is applied for the settings of the ports on the switch. By this function, you can set or reset the values for mode and Flow Control. Fig. 3-4 Port Configuration ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 25 of 72 ________________________________________________________________________ Parameter description Enable Jumbo Frames: This function support jumbo frames of up to 9600 bytes. Just tick the check box () to enable it. Default: disabled Perfect Reach/Power Saving Mode: This function supports Power Saving and perfect Reach, Just select with the Full/ Link-up/ Link-down/ Disable Default: disable Link: Show link status of this port.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 26 of 72 ________________________________________________________________________ 3-2-3. VLAN Mode Configuration Web Smart Switch supports Port-based VLAN and Tag-based VLAN (802.1q). Its VLAN mode supports 16 active VLANs and the available VLAN ID range is from 1~4094. VLAN configuration is used to divide a LAN into smaller ones.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 27 of 72 ________________________________________________________________________ 3-2-4. VLAN Group Configuration Function name Tag-based VLAN Configuration (Tag based VLAN mode) Function description The VLAN membership configuration for the selected switch can be monitored and modified here. Up to 16 VLANs are supported. This page allows for adding and deleting VLANs as well as adding and deleting port members of each VLAN. Fig.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 28 of 72 ________________________________________________________________________ Parameter description VID: VLAN identifier. Each tag-based VLAN group has a unique VID. It appears only in tag-based mode. Member: In modify function this is used to enable or disable if a port is a member of the new added VLAN, “Enabled” means it is a member of the VLAN. Just tick the check box () beside the port x to enable it.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 29 of 72 ________________________________________________________________________ Function name Port-based VLAN configuration (Port-based VLAN mode) Function description It shows the information of VLAN groups, and allows administrators to maintain them by modifying and deleting each VLAN group. User also can add a new VLAN group by inputting a new VLAN name and VLAN ID.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 30 of 72 ________________________________________________________________________ Parameter description ID (Group ID): When you want to edit a VLAN group, you must select the Group ID field. Then, you will enter Tag Base VLAN Group Setting or Port Base VLAN Group Setting page, which depends on your VLAN mode selection.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 31 of 72 ________________________________________________________________________ Parameter description Port Members: A check box is provided for each port of a private VLAN. When checked, port isolation is enabled on that port. When unchecked, port isolation is disabled on that port. By default, port isolation is disabled on all ports. 3-2-6.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 32 of 72 ________________________________________________________________________ Parameter description PoE Enabled: PoE can be enabled or disabled for each port separately. Priority: Three options are offered for the user to choose, including Normal, Low and High. Default is Normal.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 33 of 72 ________________________________________________________________________ 3-2-7. Aggregation The Aggregation (Port Trunking) Configuration is used to configure the settings of Link Aggregation. You can bundle ports by same speed, MAC, and full duplex to be a single logical port, thus the logical port can aggregate the bandwidth of these ports. This means you can apply your current Ethernet equipment to build the bandwidth aggregation.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 34 of 72 ________________________________________________________________________ 3-2-8. RSTP RSTP detects and resolves network loops, and provides backup links between switches, bridges and routers. The protocol allows a switch to communicate with other RSTP compliant switches, and to ensure only one path existing between two stations in your network environment.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 35 of 72 ________________________________________________________________________ Parameter description System Priority: System priority is used in determining the root switch, root port and designated port. The switch with the highest priority (lowest numeric value) becomes the STP root switch. If all switches have the same priority, the switch with the lowest MAC address will then become the root switch. Select a vale from the drop-down list box.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 36 of 72 ________________________________________________________________________ Fig. 3-13 RSTP Port Configuration Parameter description Protocol Enabled: Just tick the check box () beside the port x to enable RSTP protocol, then press the button to apply. Edge: Just tick the check box () beside the port x to enable edge function. Path Cost: Path cost is the cost of transmitting a frame on to a LAN through that port.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 37 of 72 ________________________________________________________________________ 3-2-9. IGMP Snooping Function name IGMP Snooping Configuration Function description IGMP Snooping lets administrators configure a switch to constrain multicast traffic by listening to Internet Group Management Protocol (IGMP). After finishing the settings, please press button to start up the function. Fig.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 38 of 72 ________________________________________________________________________ IGMP Snooping Enabled: After IGMP Enabled function start up then user can tick the check box ( ) to enable this function. Default: enabled IGMP Querying Enabled: After IGMP Enabled function start up then user can tick the check box ( ) to enable this function. Default: enabled ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 39 of 72 ________________________________________________________________________ 3-2-10. Mirroring Configuration Function name Mirror Configuration Function description Mirror Configuration is provided to monitor the traffic in the network. This switch supports one-port mirror multi-ports.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 40 of 72 ________________________________________________________________________ 3-2-11. QoS (Quality of Service) Configuration The switch offers powerful QoS function. This function supports VLAN-tagged priority that can make precedence of 8 priorities, and DSCP (Differentiated Services Code Point) on Layer 3 of network framework. Fig.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 41 of 72 ________________________________________________________________________ Fig. 3-17 802.1p Setting Function name DSCP QoS mode Function description In the late 1990s, the IETF redefined the meaning of the 8-bit SERVICE TYPE field to accommodate a set of differentiated services (DS).
24 Port Gigabit Ethernet PoE Switch – User Manual Page 42 of 72 ________________________________________________________________________ Fig. 3-18 DSCP Setting ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 43 of 72 ________________________________________________________________________ 3-2-12. Loop Detection Function name Loop Detection Configuration Function description The loop detection is used to detect the presence of traffic. When switch receives packet’s (looping detection frame) MAC address the same as oneself from port, show Loop detection happens. The port will be locked when it received the looping detection frames.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 44 of 72 ________________________________________________________________________ Parameter description Mode: Controls whether Loop Detection is enabled (as a whole). Unlock Time: The period (in seconds) for which a port will be kept disabled in the event of a loop is detected (and the port action is to shut down the port). State: Show the status of this port.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 45 of 72 ________________________________________________________________________ 3-2-13. Broadcast Strom Protection Function name Broadcast Strom Protection configuration Function description When the broadcast packets received by the switch exceed the threshold configured, the port will be blocked for a period of time which can be set.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 46 of 72 ________________________________________________________________________ Parameter description Mode: Controls whether Broadcast Strom Protection is enabled (as a whole) Packet Per Second: It is a threshold. When the broadcast packet traffic in a second is higher than the threshold configured, Broadcast Strom Protection will disable the port.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 47 of 72 ________________________________________________________________________ 3-2-14. SNMP Any Network Management System (NMS) running the Simple Network Management Protocol (SNMP) can manage devices equipped with SNMP agent, provided that the Management Information Base (MIB) is installed correctly on the managed devices.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 48 of 72 ________________________________________________________________________ have the same community name, they don’t belong to the same group. Hence, the requesting network management unit cannot access the device with different community name via SNMP protocol; if they both have the same community name, they can talk each other. Community name is user-definable with a maximum length of 15 characters and is case sensitive.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 49 of 72 ________________________________________________________________________ 3-3. Monitoring There are six functions contained in the monitoring function. ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 50 of 72 ________________________________________________________________________ 3-3-1. Statistics Overview Function name Statistics Overview for all ports Function description The section describes to the port statistics information and provides overview of general traffic statistics for all switch ports. Fig.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 51 of 72 ________________________________________________________________________ 3-3-2. Detailed Statistics Function name: Detailed Statistics Function description: Display the detailed counting number of each port’s traffic. In the Fig. 4-21, the window can show all counter information each port at one time. Fig. 3-23 Detailed Statistics for each port Parameter description: Rx Packets: The counting number of the packet received.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 52 of 72 ________________________________________________________________________ Tx Low Priority Packets: Number of Tx packets classified as low priority. Tx Broadcast: Show the counting number of the transmitted broadcast packet. Tx Multicast: Show the counting number of the transmitted multicast packet. Tx Broad- and Multicast: Show the counting number of the transmitted broadcast with multicast packet.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 53 of 72 ________________________________________________________________________ Rx Fragments: Number of short frames (< 64 bytes) with invalid CRC Rx Jabber: Number of long frames (according to max_length register) with invalid CRC Rx Drops: Frames dropped due to the lack of receiving buffer. Tx Collisions: Number of collisions transmitting frames experienced.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 54 of 72 ________________________________________________________________________ 3-3-4. RSTP Status Function name RSTP VLAN Bridge Overview Function description This screen informs about general RSTP settings and shows the current status of the Spanning Tree including root bridge and root port. Fig.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 55 of 72 ________________________________________________________________________ Function name RSTP Port Configuration Function description Enable or disable RSTP protocol on the ports that are selected and set path cost. Fig. 3-25 RSTP Port Status Parameter description Port / Group: The RSTP information is listed per port or trunk Path Cost: Path cost is the cost of transmitting a frame on to a LAN through that port.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 56 of 72 ________________________________________________________________________ State: Shows the port state (forwarding, blocking, learning or non-stp this function is disabled) 3-3-5. IGMP Status Function name IGMP Status Function description Display IGMP status. In Fig. 4-22, the window shows VLAN ID for each multicast group. Fig. 3-26 IGMP Status Parameter description VLAN Id: Show VLAN Id for each multicast group.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 57 of 72 ________________________________________________________________________ V3 Reports: When a host receives a group membership query, it identifies the groups associated with the query and determines to which groups it belongs. The host then sets a timer, with a value less than the Max Response Time field in the query, for each group to which it belongs. It Calculate the number of times of IGMPV3 report.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 58 of 72 ________________________________________________________________________ 3-3-6. PoE Status Function name PoE State Function description Display the information about the PoE status. Fig. 3-27 ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 59 of 72 ________________________________________________________________________ Parameter description Power Reservation: The watts are supplied by the PoE. The maximal power that the switch can supply (read only). Port No: Port number PD Class: Each PD is classified according to a class that defines the maximum power the PD will use. The PD Class shows the PDs class. Five classes are defined: Class 0: Max. power 15.4 W Class 1: Max. power 4.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 60 of 72 ________________________________________________________________________ 3-3-7. Ping Status Function name Ping Status Function description To set up target IP address for ping function and display ping status. In Fig. 4-24, the window shows the ping information. Fig. 3-28 Ping Parameter description Ping Parameters: Target IP address: Set up a Target IP address to ping. Count: Use drop-down menu to set number of echo requests to send.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 61 of 72 ________________________________________________________________________ Ping Results: Target IP address: Show the active target IP address. Status: Show the result of the ping status. Received replies: Show the received replies number of times. Request timeouts: Show the timeout of request. Average Response times (In ms): Shows the average response time in milliseconds ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 62 of 72 ________________________________________________________________________ 3-4. Maintenance There are five functions contained in the maintenance function. Maintenance Warm Restart Factory Default Software Upgrade Configuration File Transfer Logout ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 63 of 72 ________________________________________________________________________ 3-4-1. Warm Restart Web Smart Switch offers many approaches to reboot your switch, such as: power up, hardware reset and software reset. You can press RESET button in the front panel of your switch to reset the device and to retrieve default settings. After upgrading software, you have to reboot the device to have new configuration take effect.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 64 of 72 ________________________________________________________________________ 3-4-2. Factory Default Function name Factory Default Function description Factory Default provides the function to retrieve default settings and replace current configuration. Except the IP address setting, all settings will be restored to the factory default values when “Factory Default” function is performed.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 65 of 72 ________________________________________________________________________ 3-4-3. Software Upgrade Function name Software Upgrade Function description You can just click Browse button to retrieve the file you want in your system to upgrade your switch. Fig. 3-31 Software Upgrade ©2014 MICROSENS GmbH & Co. KG – Hamm/Germany www.microsens.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 66 of 72 ________________________________________________________________________ 3-4-4. Configuration File Transfer Function name Configuration File Transfer Function description You can backup your switch’s configuration file into your computer folder in case accident happens. In addition, uploading backup configuration file into a new or a crashed switch can save much time and avoid mistakes. Fig.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 67 of 72 ________________________________________________________________________ 3-4-5. Logout In addition to auto logout function we just mentioned in system configuration section, the switch also allows administrators to logout manually by Logout function. Function name Logout Function description The switch allows you to logout the system to prevent other users from the system without the permission.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 68 of 72 ________________________________________________________________________ 4. Maintenance 4-1. Resolving No Link Condition The possible causes for a no link LED status are as follows: The attached device is not powered on The cable may not be the correct type or is faulty The installed building premise cable is faulty The port may be faulty Mismatch of Auto-Negotiation settings 4-2. Q&A 1.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 69 of 72 ________________________________________________________________________ 5. Disclaimer All information in this document is provided “as is” and subject to change without notice. MICROSENS GmbH & Co. KG disclaims any liability for the correctness, completeness or quality of the information provided, fitness for a particular purpose of damage.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 70 of 72 ________________________________________________________________________ Appendix A Technical Specifications Features 20 (10/100/1000Mbps) Gigabit Ethernet (TP) switching ports are compliant with IEEE802.3, 802.3u, 802.3z and 802.3ab. 4 Gigabit TP/SFP fibers are dual media ports with auto detected function. Non-blocking store-and-forward shared-memory Web-Smart switched. Supports auto-negotiation for configuring speed, duplex mode.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 71 of 72 ________________________________________________________________________ Hardware Specifications Standard Compliance IEEE802.3/802.3ab/802.3z/802.3u/802.
24 Port Gigabit Ethernet PoE Switch – User Manual Page 72 of 72 ________________________________________________________________________ Cable and Maximum Length TP 1000Base-SX 1000Base-LX Cat.