User`s manual
MS-Q Imager User’s Manual A-59
Appendices
4. Press and hold down the
left
and
right
top buttons while reinserting and locking the battery.
5. Reinsert the imager in the handle attachment’s cradle, aligning the cradle with the
grooves along the sides of the main unit. Be sure that the handle’s 8-pin mini-DIN
connector inserts completely into the back of the imager.
6. Press and hold down the imager’s left and right top buttons while reinserting the
cable into the bottom of the handle attachment.
7. When the cable is fully inserted, the imager will
beep five times. The left indicator LED will be RED
and the right indicator LED will be GREEN.
8. Press and hold down both the left and right top
buttons until the left indicator LED switches off.
The imager will then cycle through several different LED patterns and emit two beeps.
This indicates that the imager is in its default mode and is ready for use. Be sure that
the imager’s memory is clear before you return to your desired settings. The following
symbols will allow you to clear the imager’s memory of commands, settings, XML
rules, and other data:
Important: For the default process to
work correctly, you must release both
buttons as soon as the left indicator
LED switches off.
Clear XML Rules Clear Memory