User`s manual

Profile Card Configuration
MS-3000 Single Head Decoder User’s Manual
4-9
4–Profile Card.
Mode 9: Timeout
Since the number of profile card settings is limited to 255, trigger timeouts
entered from the profile card can only affect a range from 0.1 seconds to
25.5 seconds, in tenths of a second.
To set Timeout, multiply the desired number of seconds for timeout by 10
and enter the result in binary format.
See mode 1 for switch settings for timeout ranges from 0.1 seconds to 5
seconds. (Although not shown for mode 1, switches 7 and 8 are OFF for 1
through 50.) See “Binary Calculations” on page 4-13 for timeout
ranges from 5.1 seconds to 25.5 seconds.
Mode 8: Bar Code Output, When to Output, External Trigger
Polarity, Match Code, Noread Message
Data Switches
Bar Code
Output
When to
Output
External
Trigger
Polarity
Match
Code
Noread
Message
12 345
Disabled As Soon as Possible Negative Disabled Disabled
Enabled
End of Read Cycle
Positive
Enabled
Enabled
Mode Switches = On
= Off
Mode Switches
= On
= Off