User`s manual
Operations Menu
MS-3000 Single Head Decoder User’s Manual
2-13
2–Menu Config.
Operations Menu
The Operations menu allows you to set the operations parameters for the
decoder.
To help visualize the menu’s organization and to locate the page number
where each topic is described, see figure 2-3.
Figure 2-3 Operations Menu Structure
Triggering Mode
–
Continuous Read
–
Continuous Read 1
Output
–
External Level
–
External Edge
–
Serial Data
–
Serial Data & Edge
End of
Read Cycle
–
Timeout
–
New Trigger
–
Timeout &
New Trigger
Timeout in
10 ms incs *
–
100
–
User Definable
(ASCII char.)
Serial Trigger
Character
–
^]
–
User
Definable
(ASCII char.)
External Trigger
Polarity
–
Positive
–
Negative
Number of
Reads
–
1
–
User
Definable
(1 to 31)
Match Code
–
Disabled
–
Enabled
Bar Code
Output
–
Enabled
–
Disabled
Number of
Labels
–
1
–
User
Definable
(1 to 6)
Operations
–
Bold text represents default settings.
Field
Separator
–
, (comma)
–
User
Definable
(ASCII char.)
* Divide the number entered on the command line by 100 for time in seconds.
Noread Message
(7 digits)
–
NOREAD
–
User Definable
(ASCII char.)
Noread
Message
–
Enabled
–
Disabled
When to
Output
–
As Soon As
Possible
–
End of Read
Cycle