Expand the MainProgram node under Tasks->MainTask. Double-click the MainRoutine
node to open the ladder logic editor. Select the Add-On tab to add the new Add-On
item. Click the AOI button and the new AOI will be added to the first rung.
The first three elements of the AOI then need to be created. The last two need to be
linked. Right-click in the first element and select New Tag on the popup menu.