Specifications
27
LAN CABLES
2009
2010
U/UTP Cat. 6A - 550 Mhz 10 Gigabit
Data transmission cables - gauge AWG 23
Codes A82750 (Box 305m) - A82756 (Coil 500m) - A82757 (Coil 1000m) – PVC
Codes A82740 (Box 305m) - A82746 (Coil 500m) - A82747 (Coil 1000m) – LSZH
Applications:
High frequency data transmission cabling systems.
IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet
Applicable standards:
EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.1
Connection system:
EIA/TIA 568 A and B
Installation:
EN 50174
Directives:
RoHS 2002/95/EC
▼ CONSTRUCTION SPECIFICATIONS
Internal conductor:
Rigid, red copper - nominal gauge AWG 24/1 or 0.51 mm²
Compliant with:
IEC 60228 cl. 1, VDE 0295 cl. 1
Isolation of single conductor:
Polyethylene (PE) thickness 0.95 mm
Classification:
Internal separator
Colours:
Blue+White/Blue, Orange+White/Orange, Green+White/Green, Brown+White/Brown
Separator:
Polyester tape
External sheath and fire behaviour:
PVC and Low Smoke Zero Halogen (LSZH)
Classification:
IEC 60332-1 (LSZH)
CEI 20-22 I CEI 20-35(PVC and LSZH)
IEC 60754-1 and 60754-2
IEC 61034 (LSZH)
Colour:
Grey (RAL 7001)
Marking:
FANTONET BY AMBRA90 - dddyy - hh:mm - U/UTP 4 PR AWG 24/1 100 OHM CATEGORY 6A EN
50288-10 IEC 60332.1 CM 75°C VERIFIED - m. 000 - (order no.)
LSZH
Sheath material
m 000
Progressive metre reference
No.
Production lot number
Code Training Nominal external Type of Package Approx.
diameter (mm) package dimensions (mm) weight (kg)
• PVC
A82750 4x2 (4 pairs) AWG 23/1 7.5 mm Box 305 m Dimensions 425x215x425 mm 12 Kg
A82756* 4x2 (4 pairs) AWG 23/1 7.5 mm Coil 500 m Ø400 mm - h 200 mm 19 Kg
A82757* 4x2 (4 pairs) AWG 23/1 7.5 mm Coil 1000 m Ø500 mm - h 300 mm 38 Kg
• LSZH
A82740 4x2 (4 pairs) AWG 23/1 7.5 mm Box 305 m Dimensions 425x215x425 mm 12 Kg
A82746* 4x2 (4 pairs) AWG 23/1 7.5 mm Coil 500 m Ø400 mm - h 200 mm 19 Kg
A82747* 4x2 (4 pairs) AWG 23/1 7.5 mm Coil 1000 m Ø500 mm - h 300 mm 38 Kg
(*) Special order
▼ ELECTRICAL SPECIFICATIONS
Impedance:
100 ± 15 (Ω)
Capacitance pF/m:
5.36 (pF/m)
Conductor DC resistance (at 20°C):
82.8 (Ω/Km)
▼ MECHANICAL SPECIFICATIONS
Operating temperature:
-15°C ÷ +70°C
Installation temperature:
-5°C ÷ +50°C
Storage temperature:
-15°C ÷ +70°C
Minimum bending radius:
8 x cable diameter (mm)
Maximum pulling strain:
70 (N/mm
2
)
▼ TRANSMISSIVE SPECIFICATIONS FOR CAT. 6A dB/100.00 m
Frequency Reference value 4.00 10.00 20.00 62.50 100.00 250.00 500.00 550.00
Attenuation
Typical 3.6 5.6 8.0 14.2 18.1 28.9 41.2 43.5
IEC 61156-5 3.8 5.9 8.4 15.0 19.1 31.1 45.3 –
NEXT
Typical 7165615350444039
IEC 61156-5 65.3 59.3 54.8 47.4 44.3 38.3 33.8 –
PSNext
Typical 6862585047413736
IEC 61156-5 63.3 57.3 52.8 45.4 42.3 36.3 31.8 –
ELFEXT
Typical 7365594945373130
IEC 61156-5 58 50 44 34.1 30 22 16 –
Return Loss
Typical 27 27 27 25.8 25 22 18 17
IEC 61156-5 23 25 25 21.5 20.1 17.3 15.2 –
PSANEXT
Typical 8585807575757575
IEC 61156-5 76.5 72.5 69.5 64.5 62.5 56.5 52 –