Specifications

25
LAN CABLES
2009
2010
7
F/UTP Cat. 6 - Double screen
Isolation PVC GR° 4 BLUE
Data transmission cables - gauge AWG 24
Screen, double sheath
Code A82876 (Coil 500m) - A82877 (Coil 1000m) – PVC
Applications:
High frequency data transmission cabling systems.
IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet
Applicable standards:
EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.1
Connection system:
EIA/TIA 568 A and B
Installation:
EN 50174
Directives:
RoHS 2002/95/EC
CONSTRUCTION SPECIFICATIONS
Internal conductor:
Rigid, red copper - nominal gauge AWG 24/1 or 0.51 mm²
Compliant with:
IEC 60228 cl. 1, VDE 0295 cl. 1
Isolation of single conductor:
Polyethylene (PE) thickness 1.10 mm
Classification:
Colours:
Blue+White/Blue, Orange+White/Orange, Green+White/Green, Brown+White/Brown
Screen:
Coupled aluminium/polyester (AL/PES) tape
External sheath and fire behaviour:
Fire retardant polyvinyl chloride (PVC-FR)
Double sheath, thickness 1.2 mm each layer
Classification:
IEC 60332-1
CEI 20-22 I CEI 20-35
CEI 20-37 IEC 60754-1 and 60754-2 IEC 61034
Colour:
Blue (RAL 5015)
Marking:
FANTONET BY AMBRA90 - dddyy - hh:mm - F/UTP 4 PR AWG 24/1 100 OHM CATEGORY 6 EN
50288-5-1 IEC 60332.1 CM 75°C VERIFIED - 0.6/1kV - PVC - m. 000 - (order no.)
m 000
Progressive metre reference
No.
Production lot number
Code Training Nominal external Type of Package Approx.
diameter (mm) package dimensions (mm) weight (kg)
• PVC
A82876 4x2 (4 pairs) AWG 24/1 9.0 mm Coil 500 m Ø 500 mm - h 300 mm 40 Kg
A82877* 4x2 (4 pairs) AWG 24/1 9.0 mm Coil 1000 m Ø700 mm - h 420 mm 80 Kg
(*) Special order
TRANSMISSIVE SPECIFICATIONS FOR CAT. 6 dB/100.00 m
Frequency Reference value 1.00 4.00 8.00 10.00 16.00 20.00 25.00 31.25 62.50 100.00 155.0 200.0 250.0
Attenuation
Typical 2.0 3.7 5.3 5.9 7.5 8.4 9.5 10.6 15.3 19.8 25.1 28.9 32.8
EIA/TIA 568/B.2 1.6 3.4 4.8 5.4 6.8 7.7 8.6 9.7 13.8 17.6 22.0 24.8 27.9
NEXT
Typical 79.9 70.3 68.8 61.2 67.1 64.8 66.6 63.3 57.3 57.1 55.0 53.9 55.9
EIA/TIA 568/B.2 74.3 65.2 60.7 59.3 56.2 54.7 53.3 51.8 47.3 44.3 41.4 39.7 38.3
ACR
Typical 78.3 67.1 64.2 56.1 60.2 57.0 58.1 54.3 44.4 40.7 32.5 28.9 29.1
EIA/TIA 568/B.2 72.2 61.4 55.4 53.3 48.6 46.3 43.8 41.2 31.9 24.5 16.2 10.8 5.4
PSNext
Typical 78.0 69.5 66.9 61.0 64.5 62.8 64.4 60.1 55.4 54.3 49.1 49.9 51.9
EIA/TIA 568/B.2 72.3 63.2 58.7 57.3 54.2 52.7 51.3 49.8 45.3 42.3 39.4 37.7 36.3
Return Loss
Typical 27.0 31.1 34.0 34.6 33.9 33.9 40.1 42.3 32.4 31.8 30.5 29.1 36.3
EIA/TIA 568/B.2 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 19.0 18.0 17.3
ELECTRICAL SPECIFICATIONS
Impedance:
100 ± 15 (Ω)
Capacitance pF/m:
5.36 (pF/m)
Conductor DC resistance (at 20°C):
82.8 (Ω/Km)
MECHANICAL SPECIFICATIONS
Operating temperature:
-15°C ÷ +70°C
Installation temperature:
-5°C ÷ +50°C
Storage temperature:
-15°C ÷ +70°C
Minimum bending radius:
8 x cable diameter (mm)
Maximum pulling strain:
70 (N/mm
2
)