Specifications

17
LAN CABLES
2009
2010
6
7
0
U/UTP Cat. 5e FLEX
Data transmission cables - gauge AWG 24/7
Codes A82600 (Box 305m) - A82606 (Coil 500m) - A82607 (Coil 1000m) – PVC
Applications:
High frequency data transmission cabling systems.
IEEE 802.3, IEEE 802.5, ATM, 100 BASET ETHERNET, 1000 BASE-T, Gigabit Ethernet
Applicable standards:
EN 50288, ISO/IEC 11801, EIA/TIA 568.B, EN 50173.1
Connection system:
EIA/TIA 568 A and B
Installation:
EN 50174
Directives:
RoHS 2002/95/EC
CONSTRUCTION SPECIFICATIONS
Internal conductor:
Flexible (strand 7x0.2 mm²) in red copper – nominal gauge AWG 24/7 or 0.54 mm²
Compliant with:
IEC 60228 cl. 1, VDE 0295 cl. 5
Isolation of single conductor:
Polyethylene (PE) thickness 0.95 mm
Classification:
Colours:
Blue+White/Blue, Orange+White/Orange, Green+White/Green, Brown+White/Brown
Separator:
Polyester tape
External sheath and fire behaviour:
Fire retardant polyvinyl chloride (PVC-FR)
Classification:
IEC 60332-1
CEI 20-22 I CEI 20-35
Colour:
Grey (RAL 7001)
Marking:
FANTONET BY AMBRA90 - dddyy - hh:mm - U/UTP 4 PR AWG 24/7 100 OHM CATEGORY 5E EN
50288-3-2 IEC 60332.1 CM 75°C VERIFIED - m. 000 - (order no.)
m 000
Progressive metre reference
No.
Production lot number
Code Training Nominal external Type of Package Approx.
diameter (mm) package dimensions (mm) weight (kg)
• PVC
A82600 4x2 (4 pairs) AWG 24/7 5.9 mm Box 305 m Dimensions 370x195x375 mm 13 Kg
A82601 4x2 (4 pairs) AWG 24/7 5.9 mm Box 305 m Ø200 mm - h 100 mm 4 Kg
A82606* 4x2 (4 pairs) AWG 24/7 5.9 mm Coil 500 m Ø400 mm - h 260 mm 20 Kg
A82607* 4x2 (4 pairs) AWG 24/7 5.9 mm Coil 1000 m Ø500 mm - h 300 mm 39 Kg
(*) Special order
TRANSMISSIVE SPECIFICATIONS FOR CAT. 5E dB/100.00 m
Frequency Reference value 1.00 4.00 8.00 10.00 16.00 20.00 25.00 31.25 62.50 100.00
Attenuation
Typical 2.3 3.8 5.4 6.0 7.5 8.4 9.2 10.1 15.2 19.4
EIA/TIA 568/B.2 2.0 4.1 5.8 6.5 8.2 9.3 10.4 11.7 17.0 22.0
NEXT
Typical 70.20 62.50 56.80 55.00 52.90 50.10 49.00 47.20 43.40 40.40
EIA/TIA 568/B.2 65.30 56.30 51.80 50.30 47.20 45.80 44.30 42.90 38.40 35.30
ACR
Typical 67.9 58.7 51.4 49.00 45.4 41.7 38.8 37.1 28.2 21.0
EIA/TIA 568/B.2 63.3 52.2 46.0 43.8 39.0 36.5 33.9 31.2 21.4 13.3
PSNext
Typical 67.2 59.5 53.8 52.0 49.9 47.1 46.0 44.2 40.4 29.3
EIA/TIA 568/B.2 62.3 53.3 48.8 47.3 44.2 42.8 41.3 39.9 35.4 32.3
Return Loss
Typical 24.60 28.80 31.60 31.80 32.20 31.20 35.00 35.00 35.70 26.20
EIA/TIA 568/B.2 20.00 23.00 24.50 25.00 25.00 25.00 24.30 23.60 21.50 20.10
ELECTRICAL SPECIFICATIONS
Impedance:
100 ± 15 (Ω)
Capacitance pF/m:
5.36 (pF/m)
Conductor DC resistance (at 20°C):
82.8 (Ω/Km)
MECHANICAL SPECIFICATIONS
Operating temperature:
-15°C ÷ +70°C
Installation temperature:
-5°C ÷ +50°C
Storage temperature:
-15°C ÷ +70°C
Minimum bending radius:
8 x cable diameter (mm)
Maximum pulling strain:
70 (N/mm
2
)