User`s manual
–
51
–
C
HAPTER
4 | Configuring the Switch
Configuring Thermal Protection
Figure 9: Configuring EEE Power Reduction
CONFIGURING THERMAL
P
ROTECTION
Use the Thermal Protection Configuration page to set temperature priority
levels, and assign those priorities for port shut-down if exceeded.
P
ATH
Configuration, Thermal Protection
COMMAND
U
SAGE
Thermal protection is used to protect the switch ASIC from overheating.
When the internal temperature of the switch exceeds a specified protection
level, ports can be turned off to decrease power consumption. Port shut
down can be prioritized based on assigned temperatures.
P
ARAM
ETE
R
S
These parameters are displayed:
Temperature settings for priority groups
◆
Priority – A priority assigned to a specific temperature. (Range: 0-3)
◆
Temperature – The temperature at which the ports with the
corresponding priority will be turned off. (Range: 0-255° C)
Port priorities
◆
Port – Port identifier.
◆
Priority – The priority level at which to shut down a port. (Range: 0-3)