User`s manual

49
C
HAPTER
4 | Configuring the Switch
Configuring Power Reduction
P
ARAM
ETE
R
S
These parameters are displayed:
LED Intensity Timers
Time – Time at which LED intensity is set.
Intensity LED intensity (Range: 0-100%, in increments of 10%,
where 0% means off and 100% means full power)
Maintenance
On time at link change – LEDs set at full intensity for a specified
period when a link change occurs. (Default: 10 seconds)
On at errors – LEDs set at full intensity when a link error occurs.
WEB
I
NTE
R
FACE
To configure LED intensity:
1. Click Configuration, Power Reduction, LED.
2. Set LED intensity for any required hour of the day. Click Add Time to set
additional entries.
3.
Set the duration of full intensity when a link change occurs.
4. Specify whether or not to use full intensity when a link error occurs.
5. Click Apply.
Figure 8: Configuring LED Power Reduction