User`s manual
39
button, 2:[#]button )
- seizure line seizure mode.
None (0) Æ when calling from IP side, choose L1 every
time if it is available.
UCD (1) Æ when calls from IP side, choose L1 for the
first time, and L2 for the 2
nd
time, (cyclic)
Note: Do not enable this function together with group (please refer to
5.18).
- 2nddial This command is necessary for setting one time dial
method use. While user would like to skip 2nddial
process, Micronet FXO Gateway must close 2nddial and
set as 0 (2nddial off). The default value is set as 1
(2nddial on).
- drule This command only works while 2nddial is off. When
user would like to make an outgoing call or receive an
incoming call shortly, it is necessary to set the following
three commands belonged to drule.
● drop: drop the dial digit.
● insert: insert the dial digit
● filter: filter the dial digit.
Note:
1. out: Through Micronet FXO Gateway to dial out to another Gateway’s
e164 number. When making an outgoing call, it is necessary to set
three commands in order, filter, insert then drop.
Example: sysconf –drule out_filter 002886 out_insert 0 out_drop 02
2. in: Through pass Micronet FXO Gateway in order to connect with
PSTN / PBX side. When making an incoming call from other Gateway,
the three commands is necessary to be set in order, drop, insert, then
filter.
Example: sysconf –drule in_drop 002886 in_insert 0 in_filter 02
3. While the specified digit would like to be deleted, use the character x
instead of any digits have configured.