Flow Control None
When configuring with a serial terminal (Eg. HyperTerminal) reset the
SP1200A and immediately press the “ESC” key. Users will see some device
information, and a “=>” prompt. Enter “config”, press “Enter” key and wait for a
few seconds for the configuration questions to appear. As you proceed, the
following questions for setting the parameters will appear on the screen. To
accept the default values, press <Enter> key.
Parameter Description
IP auto-configuration
With this option, users can specify whether the SP1200A
should get its network settings from a DHCP or BOOTP
server. For DHCP, enter “dhcp”, and for BOOTP enter
“bootp”. If user does not specify any of these, the IP auto-
configuration is disabled and subsequently you will be asked
for the desired network settings.
IP address
The IP address of the SP1200A. This option is only available
if IP auto-configuration is disabled.
Net mask
The net mask of the connected IP subnet. This option is only
available if IP auto-configuration is disabled.
Gateway address
The IP address of the default router for the connected IP
subnet. If you do not have a default router, enter 0.0.0.0. This
option is only available if IP auto-configuration is disabled.
3.3 Keyboard, Mouse, and Video
Configuration
Between the SP1200A and the host, there are two interfaces available for
transmitting keyboard and mouse data: USB and PS/2. The correct operation
of the remote mouse depends on several settings which will be discussed in
the following subsections.
3.3.1 SP1200A Keyboard Settings
The SP1200A settings for the host's keyboard type have to be corrected in
order to make the remote keyboard work properly. Check the settings in the
SP1200A Web front-end. Check the relevant sections in the user manual for
further details. Below parameters can be set via web-based UI of SP1200A.
9