User manual
Fibre to SAS/SATA II RAID Subsystem 
114 
User Manual 
Appendix 1 Volume Mapping in Dual Controller Mode 
In dual controller mode, the RAID subsystem has 2 Controllers, which work in 
Active/Standby-Standby/Active mode. 
In Active/Standby-Standby/Active mode, Volume Sets assigned even-numbered 
LUNs are active in Controller 1 and standby Controller 2, and Volume Sets assigned 
odd-numbered LUNs are standby in Controller 1 and active in Controller 2. 
NOTE: In Dual Controller mode, when using SATA disk drives (with 
dongle boards) it is recommended to create only a single Volume 
Set in a Raid Set (group of drives). For SAS disk drives, no 
problem to create several Volume Sets per Raid Set. 
NOTE: In Dual Controller mode, if Controller 1 fails, Controller 2 will take 
over. The fail over mode is called “Round Robin with Subset” 
(using MS Windows term). 
IMPORTANT: MPIO must be configured on the host system(s), in 
order for redundant LUNs (two paths via Controller 1 and 2) to 
appear as single LUNs. 