Specifications

Storage and Adapter Configuration
Item Description
Fujitsu ETERNUS2000 Model 200
This storage unit was tested by Fujitsu Limited
in a multipath configuration using PG-FC203L
(Emulex LPe1250-F8) host bus adapter
(Firmware version 1.11A5, driver version
8.2.0.48.2p) with EMPD multipath driver (driver
version V2.0L20, patch version T000973LP-1).
The test was performed with LifeKeeper for
Linux v7.1 using RHEL5 (kernel 2.6.18-164.el5).
Fujitsu
ETERNUS VS850
Certified by vendor support statement in a single
pathconfiguration and in multipath
configurations usingthe Device Mapper
Multipath Recovery Kit.
Newtech SweeperStor SATA and SAS
This storage unit was tested by a SIOS
Technology Corp. partner organization, in a
multipath configuration with dual RAID
controllers, using the QLogic PCI to Fibre
Channel Host Adapter for QLE2462 (with
Firmware version 4.03.01 [IP], Driver version
8.02.08) with storage firmware J200. Testing
was performed with LifeKeeper for Linux v6.2
with DMMP Recovery Kit v6.2 using the
following distributions and kernels:
RHEL4 DMMP
Emulex LP 11002 8.0.16.32 or later
Emulex LPe 11002 8.0.16.32 or later
Qlogic QLA 2462 8.01.07 or later
Qlogic QLE 2462 8.01.07 or later
RHEL5 DMMP
Emulex LP 11002 8.1.10.9 or later
Emulex LPe 11002 8.1.10.9 or later
Qlogic QLA 2462 8.01.07.15 or later
Qlogic QLE 2462 8.01.07.15 or later
SLES10 DMMP
Emulex LP 11002 8.1.10.9 or later
Emulex LPe 11002 8.1.10.9 or later
Qlogic QLA 2462 8.01.07.15 or later
Qlogic QLE 2462 8.01.07.15 or later
Note: DMMP is required for multipath
configurations.
SteelEye Protection Suite for Linux95