Installation guide
APPENDIX
38
• 1 LAN RJ-45 connector
• 2 SAS CH0&CH1 connector for SAS to SAS RAID controller
LED Indicators
Hard-drive carrier
• 1 single-color activity LED status indicator
• 1 two-color fault/power LED status indicator
Controller board
• 2 single-color LED status indicators for each SAS expander port,
one for link and one for the activity status
Host board
• 2 single-color LED status indicator per SAS host
• 2 single-color LED status indicator per Fibre host
• 2 single-color LED status indicators per iSCSI host
Power supply/cooling fan module
• 2 single-color LED status indicators for AC_OK and FAULT on
each power supply/cooling fan module
Power Supplies
Dual hot swap and redundant with PFC, N+1 design
• Wattage 595 W maximum continuous;
• Voltage 100–240 V rated
• Frequency 50–60 Hz
• Amperage (Max) 6.18A (120 VAC), 3.23A (230 VAC)
Dimensions
2U 12 bays 19-inch rackmount chassis
• Without handles 88.2(H) x 445(W) x 506(D)mm
• With handles 88.2(H) x 482(W) x 542(D)mm
3U 16 bays 19-inch rackmount chassis
• Without handles 132.6(H) x 445(W) x 506(D)mm
• With handles 132.6(H) x 482(W) x 542(D)mm
Subsystem Net Weight (Without Drives)
• Single 12/16 bays 16.5 kg/20.7 kg
• Dual 12/16 bays 17.5 kg/21.7 kg