Installation guide
HARDWARE INSTALLATION
27
2.3.3.2 Removing the DDR-2 SDRAM DIMM
1. Use your thumbs to gently push the release tabs at both ends
of the socket to release it from the socket.
2.3.4 Adding a Battery Backup Module (Option)
Please refer to Appendix B of user manaul for installing the BBM
in your SAS RAID subsystem.
2.4 Installing and Removing the Power
Supply/Cooling Fan Modules
The subsystem supports two separate power modules. Each of
them contains an integrated power supply and one cooling fan.
2.4.1 Installing the Power Supply/Cooling Fan
Modules
1 Carefully slide the power supply/cooling fan modules into the
empty slot.
2 Push the module back of the slot until it is î‚¿rmly seated in the
backplane connector.
3 Tighten the two thumbscrews to secure the power supply/cool-
ing fan modules.
4. Connect the AC power cords to a grounded electrical outlet and
to the power supply.