Installation guide
HARDWARE INSTALLATION
24
3. Click the drive tray latch into position, then continuing to slide 
the other drive tray into the slot.
4. Turn the key-lock to the proper position.
2.2.3 Removing Drives from the Enclosure
1. Don’t power the system off until the LED indicator on the drive 
tray stop ashing. 
2. Turn the key-lock to the unlock position.
3. Open the drive tray latch, then gently but rmly pull the drive
tray out from the slot.
2.3 Installing or Removing the SAS Series 
RAID Controller in the Subsystem
A RAID subsystem with redundant function contains two control-
lers. A RAID subsystem with non-redundant function consists of 
one controller. If two controllers are installed, a failover function is 
offered. Control and monitoring of the enclosure elements can be 
transferred from one controller to another in the event of a control-
ler failure. 
2.3.1 Installing the SAS RAID Controller in the 
Subsystem
Follow the steps below to install the SAS RAID controller in the 
subsystem:
1. Carefully slide the SAS RAID controller caddy into the empty 
slot.
2. Push the SAS RAID controller caddy back of the slot until it is 
rmly seated in the backplane connector. 
3. Put the lever toward the subsystem and tighten the
thumbscrew which located on the left side of lever of the SAS 
RAID controller caddy.










