Installation guide
HARDWARE INSTALLATION
24
3. Click the drive tray latch into position, then continuing to slide
the other drive tray into the slot.
4. Turn the key-lock to the proper position.
2.2.3 Removing Drives from the Enclosure
1. Don’t power the system off until the LED indicator on the drive
tray stop ashing.
2. Turn the key-lock to the unlock position.
3. Open the drive tray latch, then gently but rmly pull the drive
tray out from the slot.
2.3 Installing or Removing the SAS Series
RAID Controller in the Subsystem
A RAID subsystem with redundant function contains two control-
lers. A RAID subsystem with non-redundant function consists of
one controller. If two controllers are installed, a failover function is
offered. Control and monitoring of the enclosure elements can be
transferred from one controller to another in the event of a control-
ler failure.
2.3.1 Installing the SAS RAID Controller in the
Subsystem
Follow the steps below to install the SAS RAID controller in the
subsystem:
1. Carefully slide the SAS RAID controller caddy into the empty
slot.
2. Push the SAS RAID controller caddy back of the slot until it is
rmly seated in the backplane connector.
3. Put the lever toward the subsystem and tighten the
thumbscrew which located on the left side of lever of the SAS
RAID controller caddy.