4. To upgrade the controller firmware with bridge firmware 1.21:
a. Login to proRAID Manager.
b. Click menu "Administration > Service Options > Controller Services >
Upgrade Controller >".
NOTE: Please stop all IO operations to the RAID subsystem while
upgrade takes place.
NOTE: Firmware upgrade process will auto-upgrade the second
controller if you have redundant controllers in the RAID subsystem.
c. Warning message will be displayed. Click “Yes” to start upgrade process which
takes several minutes.
d. Select the controller firmware binary file (version 1.21).
e. When “Confirm Firmware Details” message box is displayed, select “Yes” to
confirm upgrade.
f. Upgrade process will start. Verify if new firmware is downloaded successfully.
5. Reset the controller(s) when prompted.
a. Controller board(s) must to be reset. Select “Yes” to reset controller(s).
b. Progress status of “Resetting Controller(s)” will be displayed.
c. Verify if new firmware is updated in Monitoring Æ System Information.