User manual
FIBRE-to-SAS/SATA RAID SUBSYSTEM
User Manual
147
exceeded <threshold value>
threshold
dummy shuttles installed.
Cool the room containing the system.
The temperature in the system has
dropped below 10C/50F
Heat the room containing the system.
RAID <name> rebuild failed to
complete
Usually followed by another warning indicating
reason.
Follow action for the other warning.
RAID <name> initialization failed
to complete
Usually followed by another warning indicating
reason.
Follow action for the other warning.
RAID <name> verify failed to
complete
Usually followed by another warning indicating
reason.
Follow action for the other warning.
RAID <name> expand failed to
complete
Usually followed by another warning indicating
reason.
Follow action for the other warning.
RAID <name> is degraded due to
disk failures
Backup data, schedule a disk replacement.
RAID <name> is inaccessible due
to disk failures
Schedule multiple disk replacements.
Restore data from last backup.
RAID <name> has no spare
available
Assign a spare disk to the RAID.
Cannot start scheduled verify on
RAID <name>
If RAID is Initialising, rebuilding, or expanding,
verify will run on next scheduled verify.
Otherwise backup data, schedule disk
replacement.
Controller hardware error Schedule controller replacement.
Firmware ID does not match; the
binary is not for this product
Get correct firmware and download to controller.
Firmware download checksum
failed, the binary may be
corrupted
Get a different firmware file and download to
controller.