User`s guide
Micron Electronics, Inc. 3-33
Chapter 3: Configuring the System
Server Menu
The Server Menu includes selections that take you to two other configuration
menus:
1. System Management
• Server Management Information
2. Console Redirection
You can make the following selections on the Server Menu itself.
Feature Choices Description
PCI IRQs to IO-APIC Disabled
mapping Enabled
PCI IRQ to External MUX Disabled
Enabled
Processor Retest No
Yes
System Management
Feature Choices Description
I2C User Defaults Disabled
System Management Mode Disabled
Enabled
System Event Logging Disabled
Enabled
Clear Event Log No
Yes
Fault Resilient Booting Disabled
Lvl-1
Lvl-2
If enabled, BIOS will describe direct
PCI interrupt connections to IO
APIC in multiprocessor table. Do
not enable if OS does not support
this feature.
Routes PCI IRQs to external
multiplexer (MUX) and inputs
PIIX4. Disables PIIX4 MUX.
If YES, BIOS clears historical
processor status and retests all
processors on next boot.
If enabled, I
2
C user default settings
will be programmed.
Enabled loads the embedded server
management firmware.
When enabled, system events will be
logged by BIOS and BMC.
Yes clears the system event log.
Determines level of Fault Resilient
Booting.