General Procedure to Change Jumper Setting
The short general procedure described here for changing a configuration setting
is the same for most of the jumper functions.
1. Observe the safety precautions at the beginning of this manual.
2. Turn off all connected peripherals, turn off system power, and
disconnect the AC power cord.
3. Remove the cover. You do not need to remove the system board
from the chassis, and you probably do not need to remove any
add-in boards.
4. Locate the configuration jumpers at the edge of the system board
toward the front of the system.
5. Move jumper to pins specified for the desired setting.
6. Reinstall the cover, connect the power cord, and turn on the
system for the change to take effect.
You may need to repeat these steps to move the jumper back to its original
setting, depending on the jumper function.
Figure 2-4. Jumpers J3J1 and J2J1