Use and Care

4
www.micromatic.com
EQUIPMENT SPECIFICATIONS
Air Cooled MMPP4303-PKG MMPP4303-PKG-3 MMPP4305-PKG MMPP4305-PKG-3
Water Cooled
MMPP4303-PKG-WC MMPP4305-PKG-WC MMPP4305-PKG-C3
Cooling Distance
350' 350' 500' 500'
Compressor HP
3/4 3/4 1 1
Glycol Pumps
2 3 2 3
Pump Type
Procon (Vane) Procon (Vane) Procon (Vane) Procon (Vane)
Pump GPH
80 80 80 80
Pump Motor HP
1/3 1/3 1/3 1/3
Voltage 220 220 220 220
Plug Type 6-15P 6-20P 6-15P 6-20P
Amps (Running) 10.6 10.6 11.0 14
Refrigerant
R134a R134a R134a R134a
Charge (oz.) 16 16 48 48
Refrigerant
Running Pressures
18 (low)
140 (high)
18 (low)
140 (high)
18 (low)
140 (high)
18 (low)
140 (high)
BTUs/H* 5,100 5,100 7,250 7,250
Dimensions
L x W x H Including
pump(s) and motor(s)
29" x 18" x 30" 29" x 24" x 30" 36" x 19" x 31 1/2" 36" x 24" x 31 1/2"
Weight (lbs) 170 190 240 260
Bath Capacity (gal) 11.5 11.5 11.5 11.5
Bath Insulation
Thickness
1.5" 1.5" 1.5" 1.5"
Approval ETL Listed ETL Listed ETL Listed ETL Listed
Micro Matic reserves the right to change specications without notice.
* Rated at 20ºF evaporator temperature and 90ºF ambient temperature.