EQUIPMENT SPECIFICATIONS
Air Cooled MMPP4301-EP MMPP4301 MMPP4301-PKG MMPP4302 MMPP4302-PKG
Water Cooled
MMPP4301-WC MMPP4301-PKG-WC MMPP4302-WC MMPP4302-PKG-WC
Cooling Distance
75' 125' 125' 250' 250'
Compressor HP 1/3 1/3 1/3 1/2 1/2
Glycol Pumps 1 1 2 1 2
Pump Type
Vertical Procon (Vane) Procon (Vane) Procon (Vane) Procon (Vane)
Pump GPH 240 80 80 80 80
Pump Motor HP 1/3 1/3 1/3 1/3 1/3
Voltage 115 115 115 115 115
Plug Type 5-15P 5-15P L5-30P 5-20P L5-30P
Amps (Running)
7.0
11.5
17.5
15.3
21.1
11.5 15.5
Refrigerant
R134a R134a R134a R134a R134a
Charge (oz.) 10 12 12 16 16
Refrigerant
Running Pressures
18 (low)
140 (high)
18 (low)
140 (high)
18 (low)
140 (high)
18 (low)
140 (high)
18 (low)
140 (high)
BTUs/H* 2,300 2,300 2,300 3,600 3,600
Dimensions
L x W x H Including
pump(s) and motor(s)
26" x 17 3/8" x
22 1/4"
29" x 18" x 27 1/2" 29” x 18" x 27 1/2" 29" x 18" x 30" 29” x 18” x 30”
Weight (lbs) 90 110 130 130 170
Bath Capacity (gal) 5 11.5 11.5 11.5 11.5
Bath Insulation
Thickness
1.5" 1.5" 1.5" 1.5" 1.5"
Approval ETL Listed ETL Listed ETL Listed ETL Listed ETL Listed
Micro Matic reserves the right to change specications without notice.