Pro-Line Wine
Cleaning Condenser Coil
Clean the condenser coil every three months. A dirty condenser will reduce the
performance of the cooling system.
Do not block airow to the perforated panel and do not operate the Pro-Line Wine unit
in environments above 100˚F.
DANGER: Power must be turned o and disconnected from the power source
whenever performing maintenance, repair, or cleaning the condensing unit.
• Disconnect unit from power supply.
Remove compressor cover panel and carefully blow out any dust or debris on or around
the condensing unit.
• Use a vacuum or compressed air to blow though the condenser coil.
THE CONDENSER MUST BE CLEANED AT REGULAR INTERVALS (30-60 DAYS).
FAILURE TO DO SO CAN CAUSE COMPRESSOR MALFUNCTION AND WILL VOID
WARRANTY.
If you keep the condenser clean you will minimize your service expense and lower your
electrical costs. Failure to maintain a clean condenser coil will cause high temperatures
and excessive run times. Continuous operation with dirty or clogged condenser coils
can result in compressor failures.
Gasket Maintenance
Gaskets require regular cleaning to prevent mold and mildew build up and also to keep
the elasticity of the gasket.
• Gasket cleaning can be done with the use of warm soapy water.
Avoid full strength cleaning products on the gasket as this can cause it to become
brittle and prevent a proper seal.
Never use sharp tools or knives to scrape or clean the gasket which could possibly tear
the gasket and rip the bellows.
Gaskets can easily be replaced and do not require the use of tools or authorized service
persons.