Operating instructions

TM 11574A-OI
2-50
Table 2-13. Before Operation Checks
Interval Item Action
EXTERIOR
Before Cargo Doors Inspect hardware for bent or broken door release handles.
Before Rear Doors Inspect hardware for bent or broken door release handles.
Before Refrigeration Unit Check refrigeration unit for security.
Install and secure loose or missing mount bolts.
Before Evaporator Fan Check for dirt or grease on evaporator fan or fan deck and clean if
necessary.
Before Evaporator Coil Check evaporator coil for cleanliness or obstructions.
Wash with fresh water.
Before Defrost Drain Pans
and Lines
Check defrost drain pans and drain lines for obstructions and clear if
necessary. Wash with fresh water.
Before Condenser Coil Check condenser coil for cleanliness.
Wash with fresh water.
Before Control Box Open control box door. Check for loose electrical connections or
hardware.
Before Electrical Cables Check electrical cable for cuts, deep abrasions, burned or discolored
wiring.
Before Moisture-Liquid
Indicator
Check color of moisture-liquid indicator.
Before Compressor Check oil level in compressor sight glass.
Before Condenser/
Evaporator Fans
Check rotation of condenser and evaporator fans.
INTERIOR
Before
Cargo Doors Inspect cargo doors for obvious damage such as cracks and holes
affecting serviceability.
Check seals for damage.
Before Lights Check light for security of components.
Before Floor Inspect container floor for punctures and obvious damage.
Inspect floor for blocked or clogged drains.