Operating instructions

TM 11574A-OI
2-40
Table 2-10 DataCORDER Pre-Trip Result Records
Test
No.
TITLE DATA
1-0 Heater On Pass/Fail/Skip Result, Change in current for Phase A, B and C
1-1 Heater Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C
2-0 Condenser Fan On Pass/Fail/Skip Result, Water pressure switch (WPS) - Open/Closed,
Change in currents for Phase A, B and C
2-1 Condenser Fan Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-0 Low Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-1 Low Speed Evaporator Fan
Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-0 High Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-1 High Speed Evaporator Fan
Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
5-0 Supply/Return Probe Test Pass/Fail/Skip Result, STS, RTS, SRS and RRS
5-1 Secondary Supply Probe Test Pass/Fail/Skip Result
5-2 Secondary Return Probe Test Pass/Fail/Skip Result
6-0 Compressor On Pass/Fail/Skip Result, Change in currents for Phase A, B and C
6-1 Not Applicable Not Used
6-2 Suction Modulation Valve
Open and Closed
Pass/Fail/Skip Result, Is current or pressure limit in effect (Y,N)
6-4 Not Applicable Not Used
6-5 Not Applicable Not Used
7-0 High Pressure Switch Closed Pass/Fail/Skip Result, AMBS, DPT or CPT (if equipped)
Input values that component opens
7-1 High Pressure Switch Open Pass/Fail/Skip Result, STS, DPT or CPT (if equipped)
Input values that component closes
8-0 Perishable Heat Pass/Fail/Skip Result, STS, time it takes to heat to 60 F (16 C)
8-1 Perishable Pull Down Pass/Fail/Skip Result, STS, time it takes to pull down to 32 F (0 C)
8-2 Perishable Maintain Pass/Fail/Skip Result, Averaged DataCORDER supply temperature
(SRS) over last recording interval.
9-0 Defrost Test Pass/Fail/Skip Result, DTS reading at end of test, line voltage, line
frequency, time in defrost.
10-0 Frozen Mode Set-up Pass/Fail/Skip Result, STS, time unit is in heat.
10-1 Frozen Mode Pull Down Pass/Fail/Skip Result, STS, time to pull down unit to 0 F (-17.7 C).
10-2 Frozen Mode Maintain Pass/Fail/Skip Result, Averaged DataCORDER return temperature
(RRS) over last recording interval.