Operating instructions

TM 11574A-OI
2-22
NOTE
The DataCORDER software uses the supply and return recorder sensors. The
temperature control software uses the supply and return temperature sensors.
(b) Generic Mode
The generic recording mode allows user selection of the network data points to be
recorded. The user may select up to a total of eight data points for recording. A list
of the data points available for recording follows. Changing the configuration to
generic and selecting which data points to record may be done using the Carrier
Transicold Data Retrieval Program.
1. Control mode
2. Control temperature
3. Frequency
4. Humidity
5. Phase A current
6. Phase B current
7. Phase C current
8. Main voltage
9. Suction modulation valve percentage
10. Discrete outputs (See Note )
11. Discrete inputs (See Note )
12. Ambient sensor
13. Compressor suction sensor
14. Compressor discharge sensor
15. Return temperature sensor
16. Supply temperature sensor
17. Defrost temperature sensor
18. Discharge pressure transducer
19. Suction pressure transducer
20. Condenser pressure transducer
NOTE
Bitmapped -- require special handling if used
Table 2-4. DataCORDER Standard Configurations.
Standard
Configuration
Description
2 sensors
(dCF02=2)
2 thermistor inputs(supply & return)
5 sensors
(dCF02=5)
2 thermistor inputs(supply & return)
6 sensors
(dCF02=6)
2 thermistor inputs(supply & return)
1 humidity input
9 sensors
(dCF02=9)
Not Applicable
6 sensors
(dCF02=54)
2 thermistor inputs(supply & return)
1 cargo probe (thermistor input)
7 sensors
(dCF02=64)
2 thermistor inputs(supply & return)
1 humidity input
1 cargo probe (thermistor input)
10 sensors
(dCF02=94)
2 thermistor inputs(supply & return)
1 humidity input
1 cargo probe (thermistor input)