IV. PREPARATION FOR USE
1-10. Visual Inspection Upon Initial Receipt
Visually inspect for the following to ensure the LFRS is intact, and there are no broken/damaged
items.
Table 1-2. Visual Inspection Upon Initial Receipt.
Component Inspection/Service
EXTERIOR
Container Check for damage or corrosion on the container surfaces. Check
for structural damage that is a hazard or degrades container
performance.
Cargo Doors Inspect door hardware (cargo doors) for bent or broken door release
handles.
Refrigeration Unit Check refrigeration unit for security.
Install and secure loose or missing mount bolts.
Evaporator Fan Motor Check evaporator fan motor mounting bolts for security.
Install and secure loose or missing mount bolts.
Evaporator Fan or Fan
Deck
Check for dirt or grease on evaporator fan or fan deck and clean if
necessary.
Evaporator Coil Check evaporator coil for cleanliness or obstructions.
Drain Pans and Drain
Lines
Check defrost drain pans and drain lines for obstructions
and clear if necessary.
Condenser Coil Check condenser coil for cleanliness.
Control Box Open control box door. Check for loose electrical connections
or hardware.
220 VAC Electrical Cable
(yellow cable)
Check electrical cable for cuts, deep abrasions, burned or
discolored wiring.
460 VAC Electrical Cable
(black cable)
Check electrical cable for cuts, deep abrasions, burned or
discolored wiring.
Moisture-Liquid Indicator Check color of moisture-liquid indicator (lower sight glass).
Compressor Sight Glass Check oil level in compressor sight glass.
Condenser And Evaporator
Fans
Check rotation of condenser and evaporator fans.