Operating instructions

TO 11574A OI
1-4
j. Rear Access Doors.
The rear access doors provide access to the storage section of the
refrigeration unit. The right-hand access door includes an escape hatch.
k. Escape Hatch Door.
The escape hatch provides a means of escape from the inside of the storage
section if the rear access doors are closed while an operator is still inside.
Table 1-1. Table of Leading Particulars.
ISO CONTAINER
Weight:
Gross Weight ....................................................................................52,910 lbs (24,000 Kg)
Tare Weight ..........................................................................................6,922 lbs (3,140 Kg)
Payload.............................................................................................45,988 lbs (29,860 Kg)
Exterior Dimensions:
Height.................................................................................................................8 ft (2.44 m)
Length..................................................................................................19 ft 10.5 in (6.06 m)
Width..................................................................................................................8 ft (2.44 m)
Interior Dimensions:
Height................................................................................................. 6 ft 11.31 in (64.7 cm)
Length.............................................................................................. 18 ft 0.38 in (134.6 cm)
Width.................................................................................................... 7 ft 6.31 in (58.4 cm)
Door Opening Height ...............................................................................6 ft 9.8 in (2.08 m)
Door Opening Width ..............................................................................7 ft 6.31 in (2.29 m)
Capacity:
Cubic Capacity............................................................................................ 944 ft
3
(26.7 m
3
)
Input Requirements:
Power....................................................................380/480 VAC or 190/230 VAC (3 phase)
Refrigerant ...................................................................... 10.8 lbs (4.9 kg) Receiver R-134a
Lubricant ................................................................7.6 US pints (3.6 liters) Castrol Icematic
REFRIGERATION UNIT
Compressor/Motor Assembly:
Number of Cylinders ........................................................................................................... 6
Model ...........................................................................................................................06DR
CFM .................................................................................................................................. 41
Weight (Dry)................................................................................................ 260 lbs (118 kg)
Approved Oil ............................................................................................... Castrol Icematic
Oil Charge Degrees ........................................................................ 7.6 US pints (3.6 Liters)
Oil Sight Glass .......................................................The oil level range, with the compressor
off, should be between the bottom and
one-eighth level of the sight glass.
Heater Termination Thermostat:
Opens .............................................................................................................. 130 F = 54 C
Closes....................................................................................... 100 (+/ 7) F = 38 (+/ 4) C
High Pressure Switch:
Cutout ......................................................................350 (+/ 10) psig = 25 (+/ 1.0) kg/cm
2
Cut-In .......................................................................250 (+/ 10) psig = 18 (+/ 0.7) kg/cm
2