(c) Support the weight of the refrigeration unit with the lifting device and move out away from
the container frame until the power connections are exposed.
(d) Disconnect all power cables that run from the container to the refrigeration unit.
(e) Move the defective refrigeration unit completely away from the container.
(f) Move a new refrigeration unit in position in front of the refrigeration unit bay of the
container.
(g) Carefully move the unit into position until the power cables from the container can be
connected to the unit.
(h) Connect all power cables from the container to the refrigeration unit.
(i) Move the unit completely in to the container bay and ensure that the bolt holes on the
new refrigeration unit align with those on the container.
(j) Install all 30 bolts and secure the new refrigeration unit in position on the container.
Figure 3-22. Replacing the Refrigeration Unit.