MICROLIFE THERMO+ ® Infrared Thermometer For safe, touch-free temperature measurement Instruction Manual a EN
Dear Customer, We thank you for purchasing the Microlife® Thermo+, the infrared thermometer that allows you to take fast and accurate touch-free temperature readings. The Microlife Thermo+ Infrared Thermometer is a high-quality product that has been designed for use with your iPhone, iPad, or iPod touch. With its unique technology, the Microlife Thermo+ delivers a reliable, heat-interference-free reading with each measurement.
Table of Contents Product Overview The Microlife Themo+ Infrared Thermometer and Application.........................3 What is included..............................................................................................4 Before Using the Microlife Thermo+ for the First Time Powering the Microlife Thermo+ Infrared Thermometer...................................5 Downloading the Microlife Thermo+ App from the App Store............................5 Creating a User Profile..............................
Product Overview The Microlife Thermo+ Infrared Thermometer and Application 2 4 1 3 3 1) Connection Slot on iPhone/iPad/iPod touch 2) Microlife Thermo+ Plug 3) Temperature Sensor 4) Light
What is included: 5 6 7 8 5) Measurement • Microlife Thermo+ Infrared Thermometer x 1 6) Report • Carrying Case x 1 7) Settings • Instruction Manual x 1 8) Users • Quick Start Guide x 1 Read the instructions carefully before using this device. Type BF applied part.
Before Using the Microlife Thermo+ for the First Time Powering the Microlife Thermo+ Infrared Thermometer Setting the Values for an Alert (optional) The thermometer is powered by your iOS device. To use the thermometer, ensure your iOS device has enough battery power. If measurement values for an alert have been recommended by a doctor, set the values for the alert. Open , and go to «Settings» to set and save the upper and lower temperature limits.
Taking Measurements with the Microlife Thermo+ Before Taking a Measurement Taking a Measurement • Do not drink or eat directly before or during a measurement, and avoid any physical exertion. • Open the «Microlife Thermo+» app automatically by connecting the thermometer to the iOS device. Alternatively, click on the app displayed on the iOS device screen. • The thermometer and the patient must remain in a fixed environment for at least 30 minutes.
Interpreting the Measurement Results Object Temperature Mode: Used to take the temperature of objects, such as liquids or surfaces, or the ambient temperature. The thermometer measures infrared energy that radiates from an object. During Measurement • To take a measurement on the forehead, place the thermometer’s sensor near the forehead (within 5 cm). Move the thermometer from the center of the forehead to the temple within 3 seconds.
Managing the Measurement Data Saving Data • Press «Save» to store the measurement results. If you do not wish to keep a measurement, press «Cancel». • To store measurement results from another thermometer, go to «Manual Input». ☞ The amount of data saved depends on the memory capacity of your iOS device. A warning message will appear when the memory is full. Delete old data to save new data. Deleting Data in a specific timeline, choose the intended period of view.
Managing a User Profile Appendix Creating a User Profile Error Messages Creating a profile for an individual user ensures that each individual's data is stored separately. Go to «User» and choose «+» to create a new user. Up to 10 profiles can be created. The thermometer is equipped with predefined error messages to notify the user of measurement discrepancies. Selecting a User Profile Go to «User», select the user listed and proceed to take a measurement.
Error Ambient Temperature Too High Description Ambient temperature is higher than: Potential cause and remedy The environment is too hot. The thermometer cannot work properly. Choose a cooler place. Ambient Temperature Too Low • 40.0 °C / 104.0 °F (Body and Object Mode) Ambient temperature is lower than: The environment is too cold. The thermometer cannot work properly. Choose a warmer place. • 16.0 °C / 60.8 °F (Body Mode) • 5.0 °C / 41.
Safety and Protection • This instrument has sensitive components and must be treated with care. • Protect the thermometer from the following: - extreme temperatures. - damage from impact or drops. - contamination and dust. - direct sunlight. - heat and cold. • Do not use the instrument if it is damaged or if you notice anything unusual about it. • Do not use the thermometer in damp environments. • Do not open up the device. It contains small parts that might be swallowed by children.
Disposal Batteries and electronic devices must be disposed of in accordance with the locally applicable regulations, not with domestic waste. Technical Specifications Product Name: Microlife® Thermo+ Infrared Thermometer FR4GAPO-M Operating Temperature: Body Mode: 16 - 40 °C / 60.8 - 104 °F Object Mode: 5 - 40 °C / 41 - 104 °F -20 - +50 °C / -4 - +122 °F Guarantee Storage Temperature: Measurement Range: This instrument is covered by a 2-year guarantee from the date of purchase.
Power Source From the connected Apple device Reference to Standards: Device standard: Device corresponds to the requirements of the standard for infrared thermometers ASTM E 1965 EN 12470-5 IEC 60601-1 IEC 60601-1-2 Electromagnetic Compatibility: Device fulfills the stipulations of the standard IEC 60601-1-2. This device complies with the requirements of the Medical Device Directive 93/42/EEC. Technical alterations reserved.
Guarantee Card Name of Purchaser Serial Number
Date of Purchase Specialist Dealer
Europe / Middle-East / Africa Asia North / Central / South America Microlife AG Espenstrasse 139 9443 Widnau / Switzerland Tel. +41 / 71 727 70 30 Fax +41 / 71 727 70 39 Email admin@microlife.ch www.microlife.com Microlife Corporation 9F, 431, RuiGang Road, NeiHu Taipei, 11492, Taiwan, R.O.C. Tel. 886 2 8797-1288 Fax.886 2 8797-1283 Email service@microlife.com.tw www.microlife.com Microlife USA, Inc. 1617 Gulf to Bay Blvd., 2nd Floor Ste A Clearwater, FL 33755 / USA Tel.